Cooling Method: Counter Flow
Ventilation Mode: Mechanical Ventilation
Material: Metal
Air Contact Form: Wet
Air Contact Way: Closed
Tower Shape: Square
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
KCF
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE, CCC
Condition
New
Drift Loss
0.002% Max
Fan
Axial Flow Type
Fan Qty
Customized
Fan Motor
Direct Driven, Maintenance Free
Spraying Pump
Low Head Lift, Large Flow Rate
Pump Qty
Customized
Pump Motor
Siemens
Casing
Ss/Ulta-Galvanized
Coil
Ss/HDG
Infill
PVC Material
Drift Eliminator
CPVC/PP
Ball Float Valve
Ss Material
Circulating Water Pipe
PVC Material
Nozzle
ABS Material
Transport Package
Container
Specification
1000kw
Trademark
CASEN
Origin
China
HS Code
84198990
Production Capacity
200sets/Month

Product Description

Less Evaporation Water Cooling Tower for Water Saving
 
Less Evaporation Water Cooling Tower for Water Saving

GENERAL DESCRIPTION
Closed cooling tower is a heat exchanger between ambient air and circulating water, so it is also called closed circuit cooler.
Compared with open cooling tower, closed type is water saving and scale less. 
There are two types(KCN/KCF) closed cooling tower of us, and we will help to choose the right one for your project.
Less Evaporation Water Cooling Tower for Water Saving

FEATURES
Please find configuration of KCF type closed cooling tower,
Less Evaporation Water Cooling Tower for Water Saving

ADVANTAGES 
1, Z720 ultra-galvanized steel casing, the steel is from POSCO, Korea.
    With galvanized 720g/sqm, it is much more durable than regular 150g/sqm steel.
2, Both Siemens pump motor and free maintenance fan motor can keep a reliable and stable running, so the down time will be less.
3, Properly designed for the commercial or industrial process cooling load, it can offer unparalleled energy efficiency and reliability.
4, The dimension of our closed cooling towers are designed according to container size for sea shipment, so it is convenient and reasonable cost for exporting.

TECHNICAL SPECIFICATIONS
From KCF-100 to KCF-2440, we can offer different capacity models closed cooling tower.
Hereby,  please check the part specifications,
Model Heat Rejection Capacity Fan Pump Operation
Weight
Fan Air Volume Power Qty. Water Volume Power
Rton m³/h KW m³/h KW KG
KCF-100 100 1 1*20000 1*0.75 1 1*28 1*0.75 3260
KCF-150 150 1 1*28000 1*1.5 1 1*28 1*0.75 3280
KCF-200 200 1 1*28000 1*1.5 1 1*28 1*0.75 3400
KCF-230 230 1 1*40000 1*3.0 1 1*28 1*0.75 3540
KCF-280 280 1 1*45000 1*4.0 1 1*28 1*0.75 3700
KCF-320 320 1 1*40000 1*3.0 1 1*53 1*1.1 3410
KCF-350 350 2 2*35000 2*2.2 1 1*53 1*1.1 5300
KCF-380 380 2 2*35000 2*2.2 1 1*53 1*1.1 5490
KCF-430 430 2 2*45000 2*4.0 1 1*53 1*1.1 5530
KCF-480 480 3 3*28000 3*1.5 1 1*70 1*1.5 9030
KCF-520 520 3 3*45000 3*4.0 1 1*70 1*1.5 9120
KCF-550 550 3 3*35000 3*2.2 1 1*84 1*2.2 10180
KCF-600 600 3 3*40000 3*3.0 1 1*84 1*2.2 10210
KCF-650 650 3 3*45000 3*4.0 1 1*84 1*2.2 10550
KCF-750 750 4 4*35000 4*2.2 1 1*150 1*3.0 11250
KCF-800 800 4 4*45000 4*4.0 1 1*150 1*3.0 11330
KCF-850 850 4 4*45000 4*4.0 1 `1*150 1*3.0 11930
Note: the 'Rated Capacity' based on standard condition: water inlet and outlet temp. 37-32degC, wet bulb temp. 28degC.

APPLICATIONS
Closed Cooling Tower can be widely used for industry of refrigeration, oil & chemical, power generation and metallurgy. 
It also can be used in other industries, such as injection molding machine, chiller, data center and quenching oil.



Less Evaporation Water Cooling Tower for Water Saving

PROJECT SITE
Less Evaporation Water Cooling Tower for Water Saving



OTHER PROJECT CASES
Less Evaporation Water Cooling Tower for Water Saving

OUR WORKSHOP
Less Evaporation Water Cooling Tower for Water Saving

EXHIBITIONS

Less Evaporation Water Cooling Tower for Water Saving

ABOUT US
Since established in 2008, Casen Heat Transfer is a professional manufacturer and OEM & ODM supplier of cooling tower. And our products had been exported to more than 50 countries and enjoy a good reputation.
Focus in this fields for 12 years, we earned a name of excellence not only for quality products but also excellent solutions.
By now, our company had passed ISO9001, ISO14001 and OHSAS18001.
And we also got 21 patents and certificates of CE, PED & SGS.

FAQ
1, Delivery Time
    15-40days (depending on stock)
2, Shipping Type
    20"GP or 40"HQ container.
3, Required Parameters  
    Use Purpose, Water Flow Rate, Water Inlet & Outlet Temperature, Ambient Wet Bulb  Temperature and Local Power Details

Contact Us
Less Evaporation Water Cooling Tower for Water Saving

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
321
Year of Establishment
2011-03-10