Spindle Cross Flow Cooling Tower Fill Replacement

Product Details
Customization: Available
Cooling Method: Cross Flow
Ventilation Mode: Mechanical Ventilation
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
321
Year of Establishment
2011-03-10
  • Spindle Cross Flow Cooling Tower Fill Replacement
  • Spindle Cross Flow Cooling Tower Fill Replacement
  • Spindle Cross Flow Cooling Tower Fill Replacement
  • Spindle Cross Flow Cooling Tower Fill Replacement
  • Spindle Cross Flow Cooling Tower Fill Replacement
  • Spindle Cross Flow Cooling Tower Fill Replacement
Find Similar Products

Basic Info.

Model NO.
Cooling Efficiency
Material
PVC/PE
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Round
Noise Level
Ordinary
Application Fields
Industrial
Certification
ISO, CE, SGS
Condition
New
Transport Package
Container
Specification
Custom
Trademark
CASEN
Origin
China
HS Code
84199090
Production Capacity
100tons/Month

Product Description

Spindle Cross Flow Cooling Tower Fill Replacement
PVC Cooling Tower Fills
Many modern cooling towers utilize efficient plastic film fills that maximizes surface area for evaporative cooling. Water is distributed onto the fill and spreads into a thin film, increasing the air-water interface and allowing waste heat to evaporate at an accelerated rate. The main factors driving fill selection are Total Suspended Solids (T SS) levels, water make-up, intended treatment, and potential for contamination.
Spindle Cross Flow Cooling Tower Fill Replacement
Size
(mm)
Width
(mm)
Height
(mm)
Thickness
(mm)
Wave depth
(mm)
850*1000 850 1000 0.3 14.5
1000*1000 1000 1000 0.3 14.5
OEM We can produce as your request
 
Brand: SPINDLE
Size:850 x 1000 mm
1300 x 1000 mm
Thickness: 0.28-0.33 mm
Flute: 16 mm
Material: PVC.
Fire Classification: M2.
Typical Sheet Size: As requested.
Color: Black, blue, transparent, or other
Working Temperature: 65 °C.
With 42% Oxygen Index.


 
Spindle Cross Flow Cooling Tower Fill Replacement

Feature:
Film fills to fit any application, and water quality level.
Widest range of flute geometries to control fouling.
High thermal performance options.
New tower construction as well as retrofit applications.




CPVC Cooling Tower Fills
CPVC cooling tower fill is an advanced product of PVC fills. The main materials of CPVC fills are chlorine and polyvinyl chloride. It has excellent high-temperature resistance, chemical resistance, high mechanical strength and fire resistance performance.

Spindle Cross Flow Cooling Tower Fill Replacement
Material: CPVC, polycarbonate, ABS, or other.
Material Grade: Flame spread rate not to exceed 25 per ASTM E-84
Working Temperature: 75°C to 85°C.
Tensile Strength: 6300 PSI.
Typical Sheet Size: As request
Color: Black, blue, transparent, or other customized colors
With 42% Oxygen Index.


Spindle Cross Flow Cooling Tower Fill Replacement
Extremely high-temperature resistance.
Compared with PVC fills and PP fills. The maximum working temperature of PVC fills is 65°C and PP is 90°C. The maximum working temperature of C can achieve 100°C. It can supply maximum pressure loading capacity but also supplies the longest service life in the high-temperature environments
Corrosion resistance.
The high content of chlorine element supplies excellent chemical sta buy, it can resist acid, alkali, salty and another organic solvent
Fire resistance performance.
Fire resistance is the most outstanding performance of CPVC cooling tower fills. It can neither be self-burning nor contribute to burning. The LOI (Limiting Oxygen Index) can achieve 46, which is the highest grade of fire resistance.

Spindle Cross Flow Cooling Tower Fill Replacement

PP Cooling Tower Fills
PP cooling tower fill, an alternative to the PVC cooling tower fills, is made of polypropylene material with superior quality and features. PP cooling tower fill is suitable for counterflow and crossflow cooling towers. It is widely used in power station cooling towers, process cooling towers, air conditioning cooling towers.

Spindle Cross Flow Cooling Tower Fill Replacement
It features higher temperature resistance than PVC cooling towers. It can remain good performance in the high temperature up to 90°C while the 65°C of PVC fill to ensure good performance in more applications.

Spindle Cross Flow Cooling Tower Fill Replacement
Another advantage of PP cooling tower fill is the attachment of block. As we all know, the PVC fills is glued together into blocks. But the PP cooling tower fills are welded into accurate honeycomb opening at the surface of the fill blocks. In this way, it can prevent PP cooling tower fill breaking up over time and breaking down of the PP fill blocks.

Spindle Cross Flow Cooling Tower Fill ReplacementSpindle Cross Flow Cooling Tower Fill ReplacementSpindle Cross Flow Cooling Tower Fill ReplacementSpindle Cross Flow Cooling Tower Fill Replacement

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now