Cooling tower for Cold Refrigeration storage
Cooling tower for Cold Refrigeration storage have water and air as cooling medium exchange heat with high-temperature Product inside the coils and bring the temperature down on basis of environment wet bulb temperature.
There are water distrubution system,condensing coils/plates,PVC Filler,Drift eliminator etc. as inside accessories and outside accessories such as pump,air inlet louver,Fan etc. completing the whole Device.
[ Technical Specification ]
The width of cooling tower evaperative condenser is no longer than 2.2m which designed specific to load container for smooth delivery.
Model |
Rated Capacity |
Fan |
Spraying Pump |
Operation Weight |
Qty. |
Power |
Air Volume |
Qty. |
Power |
Flow Rate |
RT |
KW |
m³/h |
KW |
m³/h |
KG |
KCN-15 |
15 |
1 |
1*1.1 |
1*15000 |
1 |
1*1.1 |
1*36 |
1280 |
KCN-25 |
25 |
1 |
1*1.1 |
1*15000 |
1 |
1*1.1 |
1*36 |
1550 |
KCN-35 |
35 |
1 |
1*1.1 |
1*15000 |
1 |
1*1.1 |
1*36 |
2100 |
KCN-45 |
45 |
2 |
2*1.1 |
2*15000 |
1 |
1*1.1 |
1*53 |
2300 |
KCN-55 |
55 |
2 |
2*1.5 |
2*18500 |
1 |
1*1.1 |
1*53 |
2550 |
KCN-65 |
65 |
2 |
2*1.5 |
2*18500 |
1 |
1*1.1 |
1*53 |
2600 |
KCN-80 |
80 |
2 |
2*2.2 |
2*26000 |
1 |
1*1.1 |
1*53 |
3400 |
KCN-90 |
90 |
1 |
1*5.5 |
1*60000 |
1 |
1*1.5 |
1*70 |
3800 |
KCN-105 |
105 |
1 |
1*5.5 |
1*60000 |
1 |
1*1.5 |
1*70 |
4200 |
KCN-125 |
125 |
1 |
1*5.5 |
1*80000 |
1 |
1*1.5 |
1*70 |
5380 |
KCN-135 |
135 |
1 |
1*7.5 |
1*90000 |
1 |
1*1.5 |
1*70 |
5800 |
KCN-160 |
160 |
1 |
1*11 |
1*125000 |
1 |
1*2.2 |
1*100 |
7400 |
KCN-180 |
180 |
1 |
1*11 |
1*125000 |
1 |
1*2.2 |
1*100 |
8200 |
KCN-200 |
200 |
2 |
2*4 |
2*55000 |
1 |
1*3 |
1*140 |
8700 |
KCN-220 |
220 |
2 |
2*5.5 |
2*60000 |
1 |
1*3 |
1*140 |
8900 |
KCN-240 |
240 |
2 |
2*7.5 |
2*90000 |
1 |
1*4 |
1*180 |
9200 |
KCN-255 |
258 |
2 |
2*5.5 |
2*80000 |
1 |
1*4 |
1*180 |
9400 |
KCN-275 |
275 |
2 |
2*7.5 |
2*90000 |
1 |
1*4 |
1*180 |
10500 |
KCN-290 |
290 |
2 |
2*11 |
2*125000 |
1 |
1*4 |
1*180 |
11900 |
KCN-315 |
315 |
2 |
2*11 |
2*125000 |
1 |
1*4 |
1*180 |
13350 |
KCN-330 |
330 |
2 |
2*7.5 |
2*90000 |
2 |
1*5.5 |
1*233 |
15000 |
Note: the 'Rated Capacity' based on standard condition: water inlet and outlet temp. 37-32degC, wet bulb temp. 28degC. |
[ Application ]
Heat Pump, Generating Set, Glass Melting Pit, Boiler Steam Condenses, Power Plant, Chemicals, Food, Cold Room, Pharmaceutical Factory etc.
[ Key Projects ]
[ Workshop ]
[ our Activities ]
[ Why Choose Casen ]
1, Over 12 Year Experience In Cooling Tower System
2, +1200 Projects Installation Finished Over 35 Countries Worldwide
3, Computer Software Calculation, Performance 110% Reliable
4,Company had passed ISO9001, ISO14001 and OHSAS18001;
5,21 patents and certificates of CE, PED & SGS.
6, Professional Technical Team, Personal Customization Solution For You.